The DelsaNano series is a new generation of instruments that use photon correlation spectroscopy (PCS), which determines particle size by measuring the rate of fluctuations in laser light intensity scattered by particles as they diffuse through a fluid, for size analysis measurements and/or electrophoretic light scattering (ELS), which determines electrophoretic movement of charged particles under an applied electric field from the Doppler shift of scattered light, for zeta potential determination. This series has a broad range of capabilities, including conventional static and automatic titration measurements for both size and zeta potential distributions of suspended particles in a wide range of size and concentration. The DelsaNano also can measure zeta potential of a solid surface or film. * This item has been discontinued by the manufacturer. Delsa™Nano C Attributes Sample Volume Range 30 to E-1 ml Temperature Range 15 to 90 °C Size.6 to 7 mm Depth 21.7 in Height 8.3 in Width 15 in Power Requirements 0-300 V Weight 46.3 lbs Additional Specifications Molecular Weight: 103 - 3 × 107 Daltons Size Range for Zeta Potential: 0.6 nm - 30 Μm Electrophoretic Mobility: ± 1.2 × 10-3 cm2/V.s Zeta Potential: ± 200 mV Scattering Angle (s) Size: 15º, 165º Zeta Potential: 15º, 30º Sample Concentration: 10 ppm to 40% Conductivity Range: Up to 200 mS/cm. Delsa™Nano HC Attributes Depth 21.7 in Height 8.3 in Width 15 in Weight 46.3 lbs Additional Specifications Funtion: High sensitivity sizing and zeta potential measurement of particles in fluid suspensions; Zeta potential measurement of flat surfaces.
Measurement Range Size: 0.6 nm-7 Μm Molecular Weight: 103 - 3 × 107 Daltons Size Range for Zeta Potential: 0.6 nm - 30 Μm Electrophoretic Mobility: ± 1.2 × 10-3 cm2/V.s Zeta Potential: ± 200 mV Voltage Range: 0-300 V Minimum Sample Volume Size: 30 ΜL Zeta Potential: 0.7 mL Scattering Angle (s) Size: 15º, 165º Zeta Potential: 15º, 30º Temperature Range: 15°C below ambient to 90°C Sample Concentration: 1 ppm to 40% Conductivity Range: Up to 200 mS/cm. Delsa™Nano Z Attributes Depth 21.7 in Height 8.3 in Width 15 in Weight 46.3 lbs Additional Specifications Function: Zeta potential measurement of particles in fluid suspensions; Zeta potential measurement of flat surfaces Measurement Range Size Range for Zeta Potential: 0.6 nm - 30 Μm Electrophoretic Mobility: ± 1.2 × 10-3 cm2/V.s Zeta Potential: ± 200 mV Voltage Range: 0-300 V Minimum Sample Volume Zeta Potential: 0.7 mL Scattering Angle (s) Zeta Potential: 15º, 30º Temperature Range: 15°C below ambient to 90°C Sample Concentration: 10 ppm to 40% Conductivity Range: Up to 200 mS/cm. Delsa™Nano AT Attributes Depth 12.2 in Height 11.4 in Width 9.8 in Weight 16.5 lbs Additional Specifications Number of Titrants: Maximum of three Titrant Volume Standard glass vials: 50 mL Plastic vials: 50 mL Sample Volume Minimum: 30 mL Maximum: less than 50 mL for standard vial Titrant Dispense Volume Minimum: 0.1 ΜL Circulation Flow Rate: 10 - 40 mL/min Maximum Number of pH Settings: 100 pH Probe: Fast response liquid filled glass combination electrode pH Range: 1 - 13 pH Calibration: User defineable up to three points Sample Stirrer: Magnetic.

Features Zeta Potential Distribution Measurement of Concentrated Suspensions This is the first instrument in the industry that measures zeta potential distribution of concentrated solutions using ELS. It uses the patented forward scattering through transparent electrode technology (FST) to measure zeta potential of particles in various suspension concentrations up to 40% or higher depending on particle size. Because of the Brownian broadening of scattering spectrum at high scattering angles, the common practice in measuring concentrated samples using back scattering cannot be used in zeta potential measurement.
Quick Macros 2.4 Crack. Find the best prices on used Beckman Coulter instruments, equipment, and accessories. BioSurplus has the most comprehensive and available list of used laboratory.
The FST is the only known technology that can measure zeta potential of particles in concentrated suspensions. Zeta Potential Measurement of Flat Surfaces or Samples This is the first in the industry that measures zeta potential of flat surfaces or samples using ELS. Surface charge or zeta potential of bare, treated, or coated flat surfaces or samples such as glass, metal, metal oxide, ceramics, etc. In liquid can be measured using DelsaNano. A unique approach in DelsaNano makes these measurements possible. Broadest Size and Concentration Ranges and Highest Sensitivity The DelsaNano series can measure particles as small as 6 Angstrom and as large as 7 micron with molecular weight as small as 267 Dalton in a concentration range from 1 ppm to 40%.
Download Free Havij V1.15 Pro Cracked By Hmily[lcg]. It uses precision optics to avoid light intensity and coherence loss due to fiber optics collection. The utilization of both log-scale and linear-scale correlators makes measurement of broadest size range possible.